Home
Product Catalog
News
Contact Us

Product Catalog 

Accu-Tell® Multi-Drug Rapid Test Saliva Cup

  • Accu-Tell® Multi-Drug Rapid Test Saliva Cup
  • Accu-Tell® Multi-Drug Rapid Test Saliva Cup
  • Accu-Tell® Multi-Drug Rapid Test Saliva Cup
  • Accu-Tell® Multi-Drug Rapid Test Saliva Cup
Country of Origin︰China
Minimum Order︰500 pc
Share on:

 Total 20 Related Items 
Prev1516171819Next

Product Description

Accu-Tell® Multi-Drug Rapid Test Saliva Cup

Rapid Test Urine Cup Manufacturer

Accu-Tell® ACCU-TELL® Multi-Drug Rapid Test Saliva Cup for AMP/MET/COC/OPI/THC/PCP/MTD/ /OXY/COT/BAR/BZO/BUP/PPX is a lateral flow chromatographic immunoassay for the qualitative detection of multiple drugs or metabolites in oral fluid at the cut-off concentrations.

CATALOG

Product Name

Specification

Catalog No.

Multi-2 Drug Saliva Cup

with indicator

ABT-DOA-N324

Multi-3 Drug Saliva Cup

with indicator

ABT-DOA-N325

Multi-4 Drug Saliva Cup

with indicator

ABT-DOA-N326

Multi-5 Drug Saliva Cup

with indicator

ABT-DOA-N327

Multi-6 Drug Saliva Cup

with indicator

ABT-DOA-N328

Multi-7 Drug Saliva Cup

with indicator

ABT-DOA-N329

Multi-8 Drug Saliva Cup

with indicator

ABT-DOA-N330

Multi-9 Drug Saliva Cup

with indicator

ABT-DOA-N331

Multi-10 Drug Saliva Cup

with indicator

ABT-DOA-N332

 

Product Name

Specification

Catalog No.

Multi-2 Drug Saliva Cup

without indicator

ABT-DOA-K324

Multi-3 Drug Saliva Cup

without indicator

ABT-DOA-K325

Multi-4 Drug Saliva Cup

without indicator

ABT-DOA-K326

Multi-5 Drug Saliva Cup

without indicator

ABT-DOA-K327

Multi-6 Drug Saliva Cup

without indicator

ABT-DOA-K328

Multi-7 Drug Saliva Cup

without indicator

ABT-DOA-K329

Multi-8 Drug Saliva Cup

without indicator

ABT-DOA-K330

Multi-9 Drug Saliva Cup

without indicator

ABT-DOA-K331

Multi-10 Drug Saliva Cup

without indicator

ABT-DOA-K332

 

INTENDED USE

ACCU-TELL® Multi-Drug Rapid Test Saliva Cup for AMP/MET/COC/OPI/THC/PCP/MTD/ /OXY/COT/BAR/BZO/BUP/PPX is a lateral flow chromatographic immunoassay for the qualitative detection of multiple drugs or metabolites in oral fluid at the following cut-off concentrations:

Test

Calibrator

Cut-off (ng/mL)

  (AMP)

d-

50

  (MET)

d-

50

  (THC)

THC-COOH

12

  (PCP)

10

  (COC)

Benzoylecgonine

20

Opiates   (OPI)

40

  (MTD)

30

  (OXY)

20

Cotinine(COT)

Cotinine

30

Cotinine(COT)

Cotinine

50

Methylenedioxy   ( )

d,l-Methylenedioxy

50

(BAR)

50

Benzodiazepines(BZO)

10

BUP

5

Propoxyphene   (PPX)

d-Propoxyphene

50

This assay provides only a preliminary analytical test result. A more specific alternate chemical method should be used to confirm a preliminary positive analytical result.

 

TEST PROCEDURE of Multi-Drug Rapid Test Saliva Cup

Allow the test cup, specimen, and/or controls to reach room temperature (15-30°C) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection.

1. Bring the pouch to room temperature before opening it. Remove the test from the sealed pouch and use it within one hour of opening.

2. Remove the test cup from the sealed pouch and insert the sponge end of the collector into the mouth. Actively swab the inside of the mouth and tongue to collect oral fluid for approximately 3 minutes until the sponge becomes fully saturated. At the same time, the color of indicator will be changed from colorless to pink. Gentle pressing the sponge between the tongue and teeth will assist saturation. No hard spots should be felt on the sponge when saturated.

3. Remove the collector from the mouth. Place saturated oral fluid collector into chamber and press sponge fully against the strainer to collect oral fluid.

4. Secure the cap, shake three times, and start the timer. See illustration above.

5. Wait for the colored line(s) to appear.  Read results at 10 minutes.  Do not read results after 20 minutes. We also produce Urine Cup Without Lock and Urine Cup With Lock

 

LIMITATIONS

1. ACCU-TELL® Multi Drug Rapid Test Saliva Cup provides only a qualitative, preliminary analytical result. A secondary analytical method should be used to obtain a confirmed result. Gas chromatography/mass spectrometry (GC/MS), gas chromatography/tandem mass spectrometry (GC/MS/MS), liquid chromatography/mass spectrometry (LC/MS) or liquid chromatography/tandem mass spectrometry (LC/MS/MS) are the preferred confirmatory methods. A positive test result does not indicate the concentration of drug in the specimen or the route of administration.

2. A negative result may not necessarily indicate a drug-free specimen. Drug may be present in the specimen below the cutoff level of the assay.

 

Note: The above information is for reference use only. Please refer to the product insert provided with the products before use.

Payment Terms︰TT, LC
Product Image





Related Products
Accu-Tell® HBsAg HCV Combo Rapid Test Cassette
Accu-Tell® HBsAg HCV Combo Rapid Test Cassette
Accu-Tell® HCV Rapid Test Cassette
Accu-Tell® HCV Rapid Test Cassette
Accu-Tell® HBV Rapid Test Cassette
Accu-Tell® HBV Rapid Test Cassette
Accu-Tell® HBcAb Rapid Test Cassette
Accu-Tell® HBcAb Rapid Test Cassette




Home  |  Product Catalog  |  News  |  Contact Us  |  Sitemap  |  Mobile Version

Powered by DIYTrade.com  Build your FREE website !