Home
Product Catalog
News
Contact Us

Product Catalog 

Accu-Tell® Multi-Drug Rapid Test Panel (Urine)

  • Accu-Tell® Multi-Drug Rapid Test Panel (Urine)
  • Accu-Tell® Multi-Drug Rapid Test Panel (Urine)
  • Accu-Tell® Multi-Drug Rapid Test Panel (Urine)
  • Accu-Tell® Multi-Drug Rapid Test Panel (Urine)
Country of Origin︰China
Minimum Order︰500 pc
Share on:

 Total 20 Related Items 
Prev910111213Next

Product Description

Accu-Tell® Multi-Drug Rapid Test Panel (Urine)

Multi-Drug Urine Test Panel

Accu-Tell® Multi-Drug Rapid Test Panel (Urine) is a rapid chromatographic immunoassay for the qualitative detection of multiple drugs and drug metabolites in urine at the cut-off concentrations.CATALOG

Product Name

Specimen

Catalog No.

Quantity per box

Certificate

Multi-2 Drug Panel 

Urine

ABT-DOA-E51

25T/15T

 

Multi-3 Drug Panel 

Urine

ABT-DOA-E44

25T/15T

 

Multi-4 Drug Panel 

Urine

ABT-DOA-E45

25T/15T

 

Multi-5 Drug Panel 

Urine

ABT-DOA-E31

25T/15T

CE

Multi-6 Drug Panel 

Urine

ABT-DOA-E32

25T/15T

CE

Multi-7 Drug Panel 

Urine

ABT-DOA-E73

25T/15T

 

Multi-8 Drug Panel 

Urine

ABT-DOA-E74

25T/15T

 

Multi-9 Drug Panel 

Urine

ABT-DOA-E75

25T/15T

 

Multi-10 Drug Panel

Urine

ABT-DOA-E53

25T/15T

CE

 

INTENDED USE

ACCU-TELL® Multi-Drug Rapid Test Panel (Urine) is a rapid chromatographic immunoassay for the qualitative detection of multiple drugs and drug metabolites in urine at the following cut-off concentrations:

Test

Calibrator

Cut-off (ng/mL)

  (AMP)

d-

1,000/500/300

  (BAR)

300/200

Benzodiazepines   (BZO)

500/300/200/100

  (BUP)

10

  (COC)

Benzoylecgonine

300/150/100

  (THC)

11-nor-Δ9-THC-9   COOH

150/50/25

  (MTD)

300/200

  (MET)

d-

1,000/500/300

Methylenedioxy   ( )

d,l-Methylenedioxy

500/1000

  (MOP)

300/100

(MQL)

300

Opiate   (OPI)

2,000

  (PCP)

25

Propoxyphene   (PPX)

Propoxyphene

300

Tricyclic   Antidepressants (TCA)

Nortriptyline

1,000

  (TML)

100

  (KET)

1,000/500/300

  (OXY)

100

Cotinine(COT)

Cotinine

200/100

2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine   (EDD)

2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine

300/100

(FYL)

Nor

20/10

Synthetic   (K2)

JWH-018

50/30

 

Configurations of ACCU-TELL® Multi-Drug Urine Test Panel (Urine) come with any combination of the above listed drug analytes. This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated.

 

TEST PROCEDURE of Multi-Drug Rapid Test Panel

Allow the test panel, urine specimen, and/or controls to equilibrate to room temperature (15-30°C) prior to testing.

1. Bring the pouch to room temperature before opening it. Remove the test panel from the sealed pouch and use it within one hour.

2. Remove the cap.

3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but not above the arrow on the test panel.

4. Replace the cap and place the test panel on a non-absorbent flat surface.

5. Start the timer and wait for the colored line(s) to appear.

6. The result should be read at 5 minutes. Results may be stable up to 1 hour after test initiation

 

LIMITATIONS

1. ACCU-TELL® Multi-Drug Rapid Test Panel (Urine) provides only a qualitative, preliminary analytical result. A secondary analytical method must be used to obtain a confirmed result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method.

2. There is a possibility that technical or procedural errors, as well as interfering substances in the urine specimen may cause erroneous results.

3. Adulterants, such as bleach and/or alum, in urine specimens may produce erroneous results regardless of the analytical method used. If adulteration is suspected, the test should be repeated with another urine specimen.

4. A positive result does not indicate level or intoxication, administration route or concentration in urine.

5. A negative result may not necessarily indicate drug-free urine. Negative results can be obtained when drug is present but below the cut-off level of the test.

6. This test does not distinguish between drugs of abuse and certain medications.

7. A positive test result may be obtained from certain foods or food supplements.

 

Note: The above information is for reference use only. Please refer to the product insert provided with the products before use.

Payment Terms︰TT, LC
Product Image





Related Products
Accu-Tell® HBsAg HCV Combo Rapid Test Cassette
Accu-Tell® HBsAg HCV Combo Rapid Test Cassette
Accu-Tell® HCV Rapid Test Cassette
Accu-Tell® HCV Rapid Test Cassette
Accu-Tell® HBV Rapid Test Cassette
Accu-Tell® HBV Rapid Test Cassette
Accu-Tell® HBcAb Rapid Test Cassette
Accu-Tell® HBcAb Rapid Test Cassette




Home  |  Product Catalog  |  News  |  Contact Us  |  Sitemap  |  Mobile Version

Powered by DIYTrade.com  Build your FREE website !